Water damage is a terrible thing to go through; however, it helps to know that Plumbers FL Services will be there quickly and efficiently when needed. Christian and Carlos make a great team. They are friendly, polite, and hard working. They are a credit to the Plumbers FL, and I’m glad they were here to help me. Thank you Christian and Carlos and the Plumbers FL crew. I always call Plumbers FL, and recommend their services to neighbors and friends. Thank you.

-

We have used Plumbers Florida many times in the past. The technicians are always pleasant, professional and do outstanding work. Our last experience was with William who went above and beyond our expectations. His communication skills and advise were spot on. As well as just a really, really nice man!!!

-
Water Pressure Adjustment Port Orange
Call Us: 727-228-3350


The intention of this Service Video is to demonstrate the proper method to adjust the manifold pressure.
Use for FrostFighter IDF and OHV LPNG Fired units.

Procedure:
00:23 Step 1: Remove the control box cover by unscrewing the five fasteners along its edge by the burner housing. See Figure 1 for the control box cover.

01:20 Step 2: Locate the manifold plug on one of the manifold elbows.

01:28 Step 3: With the main gas supply valve off, remove the 1/8NPT plug and install a manometer or pressure gauge capable of measuring Inches of Water Column. See Figure 2 for 1/8 NPT plug.

01:58 Step 4: Attach the gas supply line to the unit and open the main gas valve.

02:20 Step 5: Locate the manifold pressure regulator.

02:27 Step 6: Remove the regulator top cap and adjust the regulator pressure by turning the screw inside.
NOTE: Refer to the manual for proper manifold pressure settings for your unit.
ALTITUDE: No adjustments are required below 2500ft. As you increase in altitude beyond 2500, decrease the gas pressure with the procedure above. Using a combustion analyzer, ensure the CO does not exceed 50ppm.

02:54 Step 7: Once an acceptable pressure has been set, replace cap and uninstall pressure gauge.

03:36 Step 8: Replace control box cover and fasten in place.

Check out our channel for new videos or go to:

www.frost-fighter.com